Jump to the 30-second cheat sheet for the key points.
One little fix at a time, we’ll make your house a home! When low-voltage landscape lights go dark, it’s usually one of three culprits: the transformer is not sending power, a connection came loose or corroded, or the underground cable has a break. The good news is that you can troubleshoot this in a calm, step-by-step way without digging up your whole yard.

Safety first
- Unplug the transformer before opening its wiring compartment or moving any connections.
- Low voltage can still spark and a transformer plugs into standard household power, so treat it with the same respect as any outdoor electrical device.
- Use dry hands and dry tools, and avoid working during rain or when the ground is soggy.
- If you find damaged 120-volt wiring, a melted transformer, or anything that looks overheated, stop and call a pro.
How it is wired
Most low-voltage systems have:
- A transformer (120V in, typically 12V out) with one or more output terminals (often labeled COM and 12V, and sometimes multiple taps like 12/13/14/15V).
- A main low-voltage cable running through the yard.
- Fixtures that connect to that cable, commonly with pierce-style connectors or wire nuts inside a small connector housing.
A “dead line” usually means one run of cable is not delivering voltage past a certain point. The first light or two might still work, then everything downstream goes dark.
Tools and supplies
- Digital multimeter (for AC voltage and continuity testing)
- Non-contact voltage tester (optional, for checking the outlet feeding the transformer)
- Wire strippers and lineman’s pliers
- Silicone-filled waterproof wire connectors or gel-filled connectors rated for direct burial
- Replacement low-voltage cable (common is 12/2 landscape wire, but match what you have)
- Small shovel or hand trowel
- Spare MR16/G4 bulbs if your fixtures use replaceable lamps
If you like these small, confidence-building fixes, you might also like Top Home Maintenance Tips for more bite-sized wins around the house and yard.
Step 1: Confirm it is one dead line
Check the transformer controls
- If your transformer has a photocell, make sure it is not covered by mulch, a plant, or a spider web. Cover it with your hand in daylight and see if it clicks on (some do, some delay).
- If it has a timer, verify the current time and on and off schedule. Power outages can reset settings.
- If it has multiple zones or outputs, confirm you are testing the correct zone.
Look for the pattern
Walk the run and note:
- Do any lights still turn on?
- Is there a point where lights stop, like “lights up to the walkway corner work, but nothing past it”?
- Did the outage happen after aeration, edging, new planting, fence work, or digging? Those are classic cable-cut moments.
Step 2: Make sure the transformer has power
Check the outlet and GFCI
- Verify the transformer is plugged in firmly.
- Press TEST and RESET on the GFCI outlet feeding it.
- If the outlet is controlled by a switch inside the house, confirm it is on.
On indicator does not always mean output
Some transformers show a display even when the output is overloaded or a terminal is loose. That’s why the next step is the real truth-teller: measuring output voltage.
Step 3: Test transformer output voltage
Unplug the transformer, open the wiring compartment, then plug it back in for testing.
- Set your multimeter to AC volts (often marked V~).
- Touch one probe to COM and the other to the active 12V (or the voltage tap used).
- You’ll typically see something like 11 to 15 VAC, depending on tap and load.
What the reading means
- 0V or very low voltage: transformer is off, failed, or not powered, or you are on the wrong terminals.
- Normal voltage at the transformer: the problem is downstream in the cable, connections, or fixtures.
- Voltage collapses when the cable is connected: often a short (two conductors touching) or a severely overloaded run. Disconnect the run and see if voltage returns at the terminals.
If your transformer sits in a spot that gets hammered by roof runoff or puddling, addressing drainage can help prevent repeat issues. Downspout Extensions That Keep Water Away From Your Foundation is a good starting point.
Step 4: Split the problem in half
When a whole line is dead, the best strategy is to divide and conquer. Instead of testing every fixture, you create a midpoint and test there. Then you narrow it down until the bad segment is obvious.
Pick a midpoint spot
Choose a fixture or connection point about halfway down the dead run. Common easy midpoints:
- A fixture where the cable is shallow and reachable
- A junction where multiple fixtures branch off
- A spot near a bed edge (usually less digging)
Measure voltage at that midpoint
- Turn the system on.
- At the midpoint fixture, open the connector and access the two conductors.
- Measure AC voltage across the two wires.
- Voltage present: the break is farther downstream.
- No voltage: the break is upstream between transformer and that midpoint.
Repeat with a new midpoint inside the failing half. This half-splitting approach saves a lot of digging.
Step 5: Check common failure points
Pierce connectors and corroded splices
Those quick connectors are convenient, but they are frequent troublemakers. Look for:
- Green or white corrosion on copper
- Loose clamp pressure
- Broken insulation where the connector pierced
- Water pooled inside a connector housing
Fix: cut back to clean copper and remake the splice with gel-filled or silicone-filled waterproof connectors rated for direct burial.
Fixture lead failures
Sometimes the underground cable is fine, but a single fixture’s shorted lead is dragging the run down.
- Disconnect that fixture from the main cable.
- Turn the system back on.
- If everything downstream returns to life, that fixture or its lead is the culprit.
Bulbs are easy to rule out
If one fixture is dark but the rest of the line works, swap in a known-good bulb. If the fixture is integrated LED (no replaceable bulb), the whole head may need replacement.
Step 6: Find a cut underground wire
If you’ve narrowed the failure to a specific section of cable, you’re hunting for one of these:
- A clean cut from edging, aeration, shovel work, or pet damage
- A nick that corroded over time until it opened
- A crushed spot under a stone, paver, or root
Check high-likelihood spots
- Along bed edges where string trimmers run
- Where the cable crosses under a walkway
- Near recent planting holes, sprinkler work, or fence posts
- At tight bends where wire was pulled hard
Dig gently
Landscape lighting cable is usually just a few inches down. Use a hand trowel and go slowly to avoid making the problem worse.
Continuity test (power off)
This is a helpful confirmation step once you suspect a section.
- Unplug the transformer.
- Disconnect the suspect cable section so it is isolated (both conductors separated from the rest of the system).
- At one end, twist the two conductors together.
- At the other end, set the multimeter to continuity or ohms and test across the two conductors.
- Beep or low resistance: the conductors are continuous end-to-end. That section is likely intact.
- No beep or very high resistance: there is an open somewhere in that run.
Important note: Continuity testing works best when the cable is fully disconnected from other branches. If it is still tied into the system, readings can get confusing because electricity can find another path through fixtures and branches.
Step 7: Repair the cable
Use direct-burial connectors
- Cut out the damaged section back to clean, shiny copper.
- Strip insulation to the connector’s requirement (often about 1/2 inch).
- Use gel-filled or silicone-filled waterproof connectors, one for each conductor.
- Gently tug-test each wire to make sure it is secure.
- Bury the splice a few inches down, and keep it out of places that get hit by edging.
Replace a badly damaged segment
Multiple splices in one area can become a maintenance headache. If a cable was chewed, crushed, or hacked up by tools, it is often cleaner to run a fresh section from the last good connection to the next fixture.
Prevent voltage drop
Dim far-end lights can happen when the run is too long or the wire gauge is too small.
- Consider thicker wire (lower gauge number) for long runs.
- Use the correct transformer tap (some systems use 13V or 14V taps for longer runs).
- Consider splitting one long run into two shorter runs on separate terminals if your transformer supports it.
Step 8: Confirm a bad fixture
If one fixture is causing trouble, here is a simple confirmation routine:
- Turn the system on.
- Measure voltage on the main cable at that fixture connection point.
- If voltage is present but the fixture is dark, swap the bulb (if possible).
- If it is integrated LED or the socket is corroded, replace the fixture head or the entire fixture.
Watch for water intrusion
Outdoor fixtures fail faster when water gets into the socket or the internal driver. Make sure the lens and gasket areas are intact and that any wire entry points are snug.
Common symptoms
| Symptom | Likely cause | Best next check |
|---|---|---|
| Nothing works anywhere | No power to transformer, failed transformer, timer or photocell settings | Test outlet and GFCI, then test transformer output voltage |
| Some lights work, then a whole section is dark | Open splice, cut cable, failed connector | Half-split testing, inspect connectors near the last working light |
| Lights flicker or randomly go out | Loose or corroded splice, water intrusion in connector | Remake splices with waterproof connectors |
| Transformer voltage drops only when cable is connected | Short in cable or fixture lead, overload | Disconnect branches one by one to isolate the short |
| Far-end lights are dim but not dead | Voltage drop on a long run | Measure voltage at far fixture, consider thicker wire or higher tap |
When to call a pro
Low-voltage systems are homeowner-friendly, but it is smart to get help when:
- The transformer is hot, buzzing loudly, smells burnt, or shows visible melting.
- You suspect the outdoor receptacle, conduit, or house wiring has an issue.
- You have repeated trips of a breaker or GFCI that do not stop after disconnecting the landscape cable.
- The lighting is integrated into a larger system (irrigation controller tie-ins, smart panels, or complex zoning).
Keep it working
- Once each season, walk the run at night and look for dim or intermittent lights.
- After yard work, do a quick test run before burying fresh mulch or closing up beds.
- Upgrade weak connections as you find them. One good waterproof splice can prevent a whole future outage.
If this kind of steady, small maintenance is your style, you might also like Top Home Maintenance Tips for more bite-sized wins around the house and yard.
The 30-second cheat sheet
The key points from this guide, in one place.
- Start at the transformer: Check the GFCI and confirm the timer or photocell settings. Then use a multimeter on AC volts to confirm the transformer is outputting roughly 11 to 15 VAC.
- Dead section? Split the run in half: Test voltage at a midpoint fixture. If voltage is present, the break is downstream. If not, it is upstream. Repeat to narrow the bad segment fast.
- Most common failures: corroded pierce connectors, loose splices, cut cable from edging or digging, or a single fixture lead that shorts and drags the line down.
- To confirm a cable break: unplug the transformer, isolate the suspect run, and use a continuity or ohms test end-to-end (best with the run disconnected from branches).
- Fix it right: cut back to clean copper and remake splices with gel-filled or silicone-filled direct-burial connectors. If the cable is badly damaged, replace that section instead of stacking multiple splices.
- Voltage drops or dim far lights: shorten the run, use thicker cable, or use a higher transformer tap (if available) for long distances.